One machine until the load says otherwise, and a $25 monthly ceiling
Context and problem
Each table lives in the memory of the one server process (fly.toml, decision 0012), so a second machine is not a setting: it needs tables to have one owner across machines, a real piece of work. The architecture review of 2026-11-25 asked when that work should start. The server could not answer: its only signals were fly logs and Fly’s dashboard, and nothing counted connections. Homefelt is for family and friends, and its hosting is paid personally.
Options considered
- Plan for several machines now. Sticky routing by table and a lease per table in Postgres. Weeks of work for a load that may never come.
- Scale on Fly’s autoscaler. Not possible: a second machine would run the same tables twice.
- A load number, measured, and a bigger machine first. Count connections; grow the one machine while it can; start the multi-machine work only past a number.
Decision
We chose option 3 (Eduardo, 2026-11-25), with these numbers:
- The rule. The work on running more than one machine starts when peak connections pass 100, half the cap of 200 (
HOMEFELT_MAX_CONNECTIONS), on three evenings in one month. Before that, a bigger machine (more memory, a dedicated CPU) comes first. - The signal. The server exports Prometheus metrics on an internal port (
src/metrics.rs, port 9091, scraped by Fly, never onapi.homefelt.io), includinghomefelt_connections_peak. At 100 open connections it raisesconnectionsHigh, pushed to Eduardo’s phone. - The ceiling. Hosting stays under $25 a month across Fly, Neon and Vercel. Vercel stays on Hobby, which is never billed; Neon’s spending notifications and Fly’s billing dashboard show the rest. Past it Eduardo decides. Nothing scales or upgrades on its own.
- The alerts. They go to a private ntfy topic (decided 2026-11-26): from the server for load and the move log, and from a Vercel Function outside Fly for
/health, called every 5 minutes by a free external pinger.
How to read the numbers and set the alerts: deploy.md, “Watching the server”.
Consequences
- One machine stays the design, and its limits are watched rather than guessed.
- A busy evening is a notice on the phone, not an outage: the cap of 200 still refuses connections past it.
- Vercel Hobby runs crons once a day, and Pro ($20 a month) would take most of the ceiling, so a free external pinger (cron-job.org) calls the health check every 5 minutes (Eduardo, 2026-11-26).
- Revisit when the rule fires, or when the ceiling is reached.